Specimen Information
Name: Ang et al. 1985, No. 24
Type: Spiral
Comments: Flexible base, axial load=0
Reference: Ang Beng Ghee; Priestley, M.J.N.; and Paulay, T., "Seismic Shear Strength of Circular Reinforced Concrete Columns," ACI Structural Journal, January-February 1989, pp. 45-59.
Material Properties
Concrete Strength:33.1 (MPa)
Transverse Steel:Yield Stress: 310 (MPa)
Longitudinal Steel:Yield Stress: 436 (MPa) Strength: 679 (MPa)
Geometry
Diameter: 400 (mm) Cross-Section: Circular
Length: L-Inflection: 800 (mm) L-Measured: 800 (mm)
Beam Length: 1,905 (mm)
Test Configuration:Cantilever with Flexible Base
Loading
Axial Load:0 (kN)
P-D:Shear provided
L-Bottom:0
Longitudinal Reinforcement
Diameter:16 (mm)
Number of Bars:20
Reinforcement Ratio:0.032
Transverse Reinforcement
Diameter Spiral:10 (mm)
Hoop Spacing, Sv:110 (mm)
Cover to Center of Hoop Bar:20 (mm)
Reinforcement Ratio:0.77
Non-Dimensional Properties
Span-to-Depth Ratio:2
Axial Load Ratio:0
Test Results
Failure Type:Flexure-Shear
Damage Observation:Concrete Crushing: 0 (mm)
Significant Concrete Spalling: 0 (mm)
Long Bar Buckling: 0 (mm)
Long Bar Fracture: 0 (mm)
Spiral Fracture: 0 (mm)
Loss of Axial Load Capacity: 0 (mm)
Resources:Force-Displacement Hysteresis (graph)
Force Displacement Data (data)
Record Information
Version:1 (April 8, 2003)
The Structural Performance Database is a project of the Pacific Earthquake Engineering Research Center, funded by the National Science Foundation. Contact Marc Eberhard at the University of Washington with questions or comments. Report technical problems to the server administrator. Copyright 2003.